Hi, first of all 68000 POD manual distinguish from defective POD from an inoperative one, your case is the first So, first download the .PDF manual here: https://isurplus.com.au/manuals/Fluke%209000A-68000%20User%20Manual.pdf and start reading from chapter 6-1.In particual after display the "POD SELF TEST 68000 FAIL 00" message you have to perform the enhanced test by performing a read operation at address F000 0000.If the message resulting from this red operation is anything other tahn READ @ F000 000 = FF OK, the the pod failed the enhanced self test.Continue reading chapter 6.6. Il 06/07/2015 21:02, Theron Troxel via Techtoolslist ha scritto:
Just got a 68000 and tried to self-test and comes back with "POD SELF TEST 68000 FAIL 00". Any help with this error? Also, does anyone fix Fluke Pods? _______________________________________________ Techtoolslist mailing list Techtoolslist@flippers.com https://pairlist7.pair.net/mailman/listinfo/techtoolslist FTP site is: ftp://ttl.arcadetech.org/TTL/Test_Equipment Archive site: http://seven.pairlist.net/pipermail/techtoolslist/
--- Questa e-mail รจ stata controllata per individuare virus con Avast antivirus. https://www.avast.com/antivirus _______________________________________________ Techtoolslist mailing list Techtoolslist@flippers.com https://pairlist7.pair.net/mailman/listinfo/techtoolslist FTP site is: ftp://ttl.arcadetech.org/TTL/Test_Equipment Archive site: http://seven.pairlist.net/pipermail/techtoolslist/