Ness and Steve wrote:
Hello All,
My fluke 9100ft has developed a PSU fault that causes the mains to my work shop to trip after around 3 minutes when turned on. I have completely disconnected all outputs rails and bypassed the input filter and it does the same.
So I have 2 options.
1. Repair the SMPS
2. Buy a replacement SMPS
Has anyone had similar problems.
Does anyone have a spare SMPS?
Cheers
Steve
_ Check with Shy @ http://navatek.com/ He has all the Fluke parts...if no one on the list can help.
John :-#)# -- John's Jukes Ltd. 2343 Main St., Vancouver, BC, Canada V5T 3C9 Call (604)872-5757 or Fax 872-2010 (Pinballs, Jukes, VideoGames) www.flippers.com "Old pinballers never die, they just flip out" _______________________________________________ Techtoolslist mailing list Techtoolslist@flippers.com http://seven.pairlist.net/mailman/listinfo/techtoolslist FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment Archive site: http://seven.pairlist.net/pipermail/techtoolslist/