Feb/Apr 2014. http://www.ukvac.com/forum/fs-andysarcade-moving-sale-listing_topic337174.ht ml Welcome to the US Andy :) -----Original Message----- From: Techtoolslist [mailto:techtoolslist-bounces@flippers.com] On Behalf Of John Robertson Sent: Thursday, July 10, 2014 11:10 PM To: techtoolslist@flippers.com Subject: Re: [Techtoolslist] B&K 490 power conversion On 07/10/2014 5:01 PM, Andrew Welburn wrote:
hi all..
I have a B&K 490, that i got in the UK, but now i've moved to the USA i need to run it on 110v...
http://www.andysarcade.net/pix/DSC_2706.JPG
The label indicates it may be switcahble internally between the two voltages.. but i opened it up and stuff is not easy to get to..
The schems in my manual only show 117vAC input, not even the 234v stated..
So.. anyone else done this? anyone seen both taps? i dont want to pull it apart further without knowing its actually possible, the frame is quite compacted with stuff.
thanks!
The 490B manual has taps on the transformer (close to the chassis) for setting the line voltage - page 3: ftp://ttl.arcadetech.org/TTL/Test_Equipment/B&K/ When did you move to this side of the pond? John :-#)# -- How to subscribe or unsubscribe from TTL http://seven.pairlist.net/mailman/listinfo/techtoolslist _______________________________________________ Techtoolslist mailing list Techtoolslist@flippers.com http://seven.pairlist.net/mailman/listinfo/techtoolslist FTP site is: ftp://ttl.arcadetech.org/TTL/Test_Equipment Archive site: http://seven.pairlist.net/pipermail/techtoolslist/