At 14:13 02-02-02 , you wrote: Yes Try TELIX Dos based software it's Ideal for the job I use it all the time if you don't have it drop me a line Off-list. I have attached a 1k plain text file of operating instructions should anyone else on the list need them. Regards Pete (Invadar)
What type of software do you guys use when interfacing the 9010A to a computer via a 232 port?
Is there any software that will run on an old 386 computer?
Thanks, Kev
To UNSUBSCRIBE from techtoolslist, send a message with "UNSUBSCRIBE" in the message body to: techtoolslist-request@flippers.com. Please direct other questions, comments, or problems to jrr@flippers.com.
Fluke ? PC Transfer Setup (should match settings on the Fluke) PC Run Telix Set Parameters 9600 Baud, no parity, 8 data bits, 1 stop bit Alt-O Terminal Options J,K,L - ON C - TTY Fluke ? PC Transfer Fluke Load program/tape into Fluke memory. Press AUX I/F PC ALT - R Protocol prompt - ASCII "Enter file name" Press Return Fluke If you want an ASCII file (i.e. printer format), press PROG on Fluke. Fluke If you want BINARY FORMAT (Fluke executable format), press WRITE on Fluke. PC ? Fluke Transfer Setup as before PC ALT - S Select ASCII protocol Select the desired file and press the RETURN key once to put selected file in "Tagged Files" box. Fluke Press AUX I/F Press READ At the "Are you sure" prompt hit YES. "Aux Receiving" prompt. PC Press F10 If all's well the line indication at the bottom left of the status bar should be incrementing.