i took a known good board set and tried the same thing running
 fluke learn start 0 - ffff
i just get pod timed out
or pod timed out and reset when i hold the reset line high
and  tried to get the outrun script from fide to run it will not go past address 0000
i did try to set trap active to "no" and pod  just times out
has anyone ran a script on this board
i have 2 sets 1 good cpu and 1 bad cpu and 2 good video
the fluke does the same with the good and bad cup brd
on the good cpu board it will run the game with run uut
the bad just keeps resetting neither will let the fluke run
i did check the pod with a bus test (self test) it comes up fine
i must be missing something
any help ??
thanks tony
On Sun, 24 Apr 2005 18:42:33 -0400, Adam Courchesne wrote:
>>ÊHit setup on the 9010, hit more until you get to 'set trap active
>>
>Êforce line' set it to 'no' .. no >need to disable WD.
>
>ÊAssuming the reset signal is only used to reset the micro. ÊIf it
>Êgoes to other registers, etc you Êcould run into problems getting
>Êthe board to run. -Adam ====================